What does the 50 L/s kitchen fan rule mean for my Kanata reno?
What does the 50 L/s kitchen fan rule mean for my Kanata reno?
Ontario's Building Code (clause 9.32.3.7) requires a supplemental exhaust fan rated at not less than 50 L/s to be installed in each kitchen. That is the minimum capacity the fan must carry; ask the City's Building Code Services how that clause applies to your specific renovation, because these are minimums written for new work.
There are two situations where the 50 L/s fan is not required. The first is where the only exhaust air intake for the principal ventilation fan in the dwelling is already located in the kitchen. The second is where the principal fan can be switched by a manual switch in the kitchen, labelled "KITCHEN EXHAUST", to run at not less than 2.5 times its normal minimum rate. If neither of those conditions applies to your Kanata home, the supplemental fan is what the Code requires.
A few other Code details from the same section that bear on how the fan is installed. The fan is controlled by a manual switch in the room it serves (9.32.3.7.(6)), and a manual switch overrides any automatic control (9.32.3.7.(8)). A kitchen fan intake other than a range hood serving the cooktop goes in the ceiling or on the wall at least 2 m above the floor (9.32.3.7.(5)). The ductwork must be noncombustible and corrosion-resistant, lead directly outdoors with no connections to other ducts, and carry a grease filter at the intake end (9.32.3.11). The exterior outlet needs a backdraft damper, and its bottom must sit at least 100 mm above the ground or any lower horizontal surface (9.32.3.13). Any duct running through unheated space is insulated to at least RSI 0.5. All of these are Code minimums for new work; ask the City how they apply to your renovation.
Whether a new duct through an exterior wall needs a City building permit is not named on the City's exempt or permit lists. Ask the City's Building Code Services before the work starts.
When you have two written quotes in front of you, set them side by side and check that each one names the fan's rated capacity, the full duct path to the exterior, who supplies and installs the backdraft damper, whether a new exterior wall penetration is included, and which party is responsible for pulling any permit the City requires.
Related service: Range Hood & Kitchen Exhaust What it costs: Range hood and exhaust
Want this done at your place?
Tell us what you want to change in your kitchen and we'll send it to local Ottawa kitchen renovation contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.
Kitchen Reno IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.
Ready to Get Quotes?
Find local kitchen renovation contractors in Ottawa. Free matching, no obligation.