What does Ontario's Building Code require for a kitchen exhaust fan?
What does Ontario's Building Code require for a kitchen exhaust fan?
Ontario's Building Code (clause 9.32.3.7) requires a supplemental exhaust fan with a rated capacity of not less than 50 L/s to be installed in each kitchen. Two exceptions apply: one where the only exhaust air intake for the principal ventilation fan is already in that kitchen, and one where the principal fan can be switched to not less than 2.5 times its minimum normal rate by a manual switch in the kitchen labelled "KITCHEN EXHAUST".
These are minimums for new work; ask the City how they apply to your renovation.
Controls and placement
The fan must be controlled by a manual switch in the room it serves, and that manual switch overrides any automatic control (9.32.3.7.(6)). A kitchen fan intake that is not a cooktop hood must be in the ceiling or on a wall at least 2 m above the floor (9.32.3.7.(5)). The Code sets no sone rating for kitchen fans.
For the duct that carries the air outside, clause 9.32.3.11 sets out the material and routing rules. The duct must be noncombustible and corrosion-resistant, must lead directly to the outdoors with no connections to other exhaust fans or ducts, and must have a grease filter at the intake end (9.32.3.11.(6)). The duct cannot discharge into any heated or unheated enclosed space (9.32.3.11.(2)). Where the duct passes through unheated space it must be insulated to at least RSI 0.5 (9.32.3.11.(3)). Joints are sealed with mastic, metal foil duct tape or the manufacturer's specified sealants (9.32.3.11.(8)). The exhaust outlet on the exterior must have a backdraft damper, and the bottom of the outlet must sit at least 100 mm above the ground or any lower horizontal surface (9.32.3.13.(11) and 9.32.3.13.(8)).
A note on recirculating (ductless) hoods: we did not find whether one meets the requirements of 9.32.3.7 either way. Ask the City or your designer before choosing one.
On make-up air, clause 9.32.3.8 applies only in dwelling units that have a fuel-fired space-heating appliance or fuel-fired water-heating appliance of other than a direct-vented or mechanically vented type. Whether that condition exists in your home is something your designer or contractor checks by looking at your heating and water-heating appliances. The Code gives no CFM figure and no hood size that triggers the make-up air requirement.
A new duct through an exterior wall is not named on either the City's exempt or permit list; ask the City's Building Code Services before the work starts. The electrical connection for the fan is an ESA matter, not a City permit: the Electrical Safety Authority requires a notification to be filed before the work starts, and if you hire someone for that wiring, Ontario law requires them to be a Licensed Electrical Contractor.
Make sure your quote spells out which duct route is planned, what the outlet termination looks like, and how the fan switch is wired, all in writing before any work begins.
Related service: Range Hood & Kitchen Exhaust What it costs: Range hood and exhaust
Want this done at your place?
Tell us what you want to change in your kitchen and we'll send it to local Ottawa kitchen renovation contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.
Kitchen Reno IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.
Ready to Get Quotes?
Find local kitchen renovation contractors in Ottawa. Free matching, no obligation.