Range Hood and Kitchen Exhaust in Ottawa: the Code Minimums, Not a Price
No published price range
The range hood prices we found did not agree between independent sources. This page lists Ontario's Building Code minimums instead.
A range hood quote is easier to compare against the rules than against a price. The table lists what Ontario's Building Code sets for a kitchen exhaust fan in a house. These are minimums for new work; ask the City how they apply to your renovation.
Last reviewed October 1, 2026. Published figures, not quotes; yours will differ. How we set these ranges
What Ontario's Building Code sets
| Item | Minimum for new work | Clause |
|---|---|---|
| Kitchen exhaust fan | Rated capacity not less than 50 L/s, with exceptions where the principal ventilation fan serves the kitchen | 9.32.3.7.(1)-(3) |
| Switch | A manual switch in the room the fan serves | 9.32.3.7.(6) |
| Cooking-fan duct | Noncombustible and corrosion-resistant, leading directly to the outdoors with no connection to other fans or ducts, with a grease filter at the intake | 9.32.3.11.(6) |
| Where a duct may not end | Not into heated or unheated enclosed spaces | 9.32.3.11.(2) |
| Outdoor outlet | A backdraft damper; the bottom not less than 100 mm above the ground | 9.32.3.13.(8), (11) |
| Make-up air | Only in dwelling units with a fuel-fired space-heating or water-heating appliance of other than direct-vented or mechanically vented types, with exemptions in (6) to (8) | 9.32.3.8.(1), (2) |
Whole-kitchen price ranges are on the kitchen cost overview; this page carries none.
Get quotes for thisWho is involved in this job
City of Ottawa
A range hood ducted through an exterior wall is not named on either of the City's lists. Ask Building Code Services before the wall is opened.
ESA
Wiring a new hood or a new circuit for it is electrical work: a notification to ESA, and if you hire someone for it, a Licensed Electrical Contractor.
What the quote should say
- The fan's rated capacity in L/s, as the Code states it, applies to new work; ask the City how it applies to your renovation.
- The duct route to the outdoors and the duct material.
- The outdoor outlet with its backdraft damper.
- Whether 9.32.3.8 make-up air applies to your house, and the reason, since that clause applies to new work; ask the City how it applies to your renovation.
- Who files the ESA notification for the wiring.
Kitchen Reno IQ answers on this job
- Range hood with a new duct outside: any published Ottawa price?
- What does the 50 L/s kitchen fan rule mean for my Kanata reno?
- When does Ontario's Code call for make-up air with a range hood?
- Venting a kitchen hood duct into the attic of an Ottawa house: allowed?
- Recirculating range hood in an Ottawa condo kitchen: does it meet the fan rule?
Quick answers
What does the Code say about recirculating hoods?
The Code text we read says nothing about recirculating hoods either way. Ask the City or your designer before relying on one.
When does the Code call for make-up air?
Article 9.32.3.8 applies to dwelling units with a fuel-fired space-heating or water-heating appliance of other than direct-vented or mechanically vented types, with exemptions in (6) to (8). There, an exhaust device other than the principal ventilation fan needs outdoor make-up air from a fan rated at not less than its exhaust capacity and not more than that plus 10%. That applies to new work; ask the City how it applies to your renovation.