Does the backsplash behind my Ottawa range need fire protection?

Question

Does the backsplash behind my Ottawa range need fire protection?

Answer from Kitchen Reno IQ

Ontario's Building Code addresses what sits above and beside a cooktop, and the answer turns on where your backsplash is relative to the burners or elements.

The Code (9.10.22.3) sets out which surfaces need protection. Combustible wall framing, finishes or cabinets within 450 mm of the cooktop must be protected above the burners by gypsum board at least 9.5 mm thick, or a material with a 10-minute fire-resistance rating and a flame-spread rating of not more than 25. However, the Code carves out an explicit exception: countertop splash boards or back plates do not need that protection (9.10.22.3.(2)). A backsplash that sits directly behind the cooktop and reads as a splash board or back plate falls within that exception.

What sits directly above matters separately. Framing, finishes and cabinetry installed directly above the cooktop location must be at least 750 mm above the level of the burners or elements (9.10.22.2.(1)). That distance can come down to 600 mm if the material is noncombustible or if a metal hood projects at least 125 mm beyond the framing, finishes and cabinets above (9.10.22.2.(2)). Cabinets at least 450 mm above the burners do not need the gypsum-board protection, except those directly above the cooktop (9.10.22.3.(3)).

These are minimums for new work. Ask the City's Building Code Services how they apply to your renovation before the work starts, particularly if you are opening the wall behind the range or changing the cabinet layout above it.

A few practical points for your quote:

  • Confirm with your contractor whether the backsplash material is combustible and where it sits relative to the 450 mm zone.
  • If you are tiling the backsplash, tile work is covered at ottawatiling.com.
  • Appliance installation instructions can require clearances beyond what the Code sets; check your range's manual for its own figures.
Before the tile or panel goes in, ask your contractor to measure the distance from the burners to every combustible surface above and beside the cooktop and confirm in writing how the Code clearances are met.
Ottawa Kitchen Renos

Want this done at your place?

Tell us what you want to change in your kitchen and we'll send it to local Ottawa kitchen renovation contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.

Fields marked are required.

We won't call you. There's no phone box above because we don't ask for one — your estimate comes by email, on your time.

Request received We’ve sent your details to local Ottawa kitchen renovation contractors. Interested contractors reply by email. A confirmation is on its way to your inbox.

Kitchen Reno IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.

Ready to Get Quotes?

Find local kitchen renovation contractors in Ottawa. Free matching, no obligation.

Find a Kitchen Contractor